OxiMax Pulse Oximetry
OxiMax Technology

 

A small, digital memory chip resides within every Nellcor OxiMax sensor, transmitting sensor-specific data to the monitor to enhance pulse oximetry performance and provide responsive, clinician-friendly features.

 

Downloads:
Technology Overview of the Nellcor OxiMax Pulse Oximetry System

Performance That Speaks to You

With the OxiMax® Pulse Oximetry System, Nellcor embarks on a new technology platform that enables us to break free from the past and bring you pulse oximetry like you’ve never experienced before. Previously, sensor calibration resided within the monitor, and sensor designs had to conform to the preprogrammed data in order to calculate oxygen saturation (SpO2). Now a digital memory chip is embedded in the sensor itself that contains all the calibration and operating characteristics for that sensor design. This gives the monitor the flexibility to operate accurately with a diverse range of sensor designs, while opening up a whole new world of pulse oximetry innovation that will help you provide better patient care.

Be sure to read our white paper titled "Technology Overview of the Nellcor OxiMax Pulse Oximetry System", which is available from the Downloads section of this page.

OxiMax Pulse Oximetry System — Platform for the Future
The OxiMax system will seamlessly accommodate future sensor developments that expand clinical applications for pulse oximetry monitoring.

The complete system includes OxiMax monitors, including the N-600 Pulse Oximeter, and the family of Nellcor OxiMax sensors.*

Sensor-Monitor Communication
A unique communication link between the OxiMax pulse oximeter and sensor empowers the monitor to convey valuable information to caregivers:

  • The Sensor Messages function enables the OxiMax monitor to display troubleshooting tips to help clinicians optimize sensor placement.
  • Sensor Event Report allows alarm event history to travel with the patient for quick assessment throughout the hospital.

Limitations of Monitor-Based Calibration
Click to view larger Chart
Traditional pulse oximetry requires one calibration curve or a limited set of curves to be programmed within the monitor. Sensor designs must conform to the preprogrammed data to accurately calculate arterial oxygen saturation (SpO2). OxiMax technology moves the sensor’s specific calibration information into the sensor, providing infinite latitude in sensor design.




* When OxiMax sensors are used with previous-generation Nellcor and Nellcor-compatible monitors, many OxiMax system features are not accessible. Because of their unique performance characteristics, the MAX-FAST® Forehead Sensor and SoftCare Nonadhesive Sensors do not operate with previous-generation Nellcor monitors.

 
 